Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Oral Maxillofac Surg ; 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37665393

RESUMO

PURPOSE: Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?". METHODS: This systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters. RESULTS: Sixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction). CONCLUSION: It can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.

2.
Antibiotics (Basel) ; 12(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37370313

RESUMO

Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.

3.
Cranio ; : 1-7, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36607231

RESUMO

OBJECTIVE: To critically evaluate the literature and answer the question: "Is there an association between depression and temporomandibular disorder (TMD) in adults?" METHODS: The personalized search strategy was applied to PubMed, Embase, Web of Science, and Scopus databases. Articles were selected in two stages according to the eligibility criteria. The Joanna Briggs Institute (JBI) tool was used to analyze the risk of bias according to the type of study. RESULTS: The included articles presented a moderate risk of bias. Based on the studies, individuals with TMD have higher levels of depression compared to the control group. There is also a direct association in that individuals with depression are more susceptible to developing TMD. CONCLUSION: There is a probable association between depression and TMD in adults. However, more studies with high methodological quality are needed to confirm this finding.

4.
Cranio ; : 1-12, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36538025

RESUMO

OBJECTIVE: To answer the question, "Is there any association between sleep disorder and temporomandibular joint dysfunction (TMD) in adults?" METHODS: This study followed PRISMA guidelines and was registered in PROSPERO. As eligibility criteria, observational studies that evaluated the association between sleep disorder and TMD were included. Exclusion criteria included a) studies that evaluated sleep quality and not the association of sleep disorders with TMD, b) experimental studies, book chapters, conference proceedings, and systematic reviews. The Joanna Briggs Institute tool was used to assess the risk of bias. RESULTS: In the literature search, 3425 articles were found. After the exclusion of duplicates, 2752 were selected for reading the title and abstract, of which 26 were read in full, and 18 met eligibility criteria. CONCLUSION: The association of sleep bruxism with TMD is controversial. While, for obstructive sleep apnea, insomnia, snoring, and gastroesophageal reflux, the analyzed studies showed a positive association.

5.
Rev. odontol. UNESP (Online) ; 48: e20190019, 2019. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1043174

RESUMO

Resumo Introdução A modificação físico-química da superfície de mini-implantes utilizados no suporte de overdentures pode influenciar o desempenho mecânico dos mesmos. Objetivo Avaliar a influência de um tratamento de superfície do tipo nanométrico no desempenho mecânico de novos designs de mini-implantes. Material e método Foram utilizados 40 mini-implantes (Ti-6Al-4V), com Ø 2 mm × 10 mm de comprimento e dois designs diferentes, rosqueado e helicoidal, divididos em quatro grupos (n=10), de acordo com o modelo e a presença ou a ausência de tratamento superficial. O desempenho mecânico foi avaliado por meio de torque de inserção e ensaio de arrancamento em cilindros ósseos suínos. Análise de variância ANOVA e teste de Tukey, com significância de 5%, foram utilizados para análise estatística dos dados. Resultado Foi observada diferença estatisticamente significante entre os grupos com e sem tratamento para torque de inserção (p<0,001), e ensaio de arrancamento (p=0,006), sendo a maior média para o grupo com tratamento, independentemente do design. Na comparação entre os designs, o rosqueado apresentou média significativamente maior (p<0,001) que o helicoidal. Conclusão: O tratamento de superfície nanométrico viabilizou melhor desempenho mecânico dos mini-implantes avaliados. Com relação aos novos designs testados, o rosqueado apresentou resultados superiores ao helicoidal.


Abstract Introduction The physical-chemical modification of the surface of mini-implants used in the support of overdentures can influence the mechanical performance and survival of the same. Objective To evaluate the influence of a nanometric surface treatment on the mechanical performance of new mini-implant designs. Material and method 40 mini-implants (Ti-6Al-4V) with Ø 2 mm x 10 mm in length and two different designs, threaded and helical, were divided into four groups (n = 10) according to model, presence or absence of surface treatment. The mechanical performance was evaluated by means of insertion torque and pullout test in swine bony cylinders. Analysis of variance ANOVA and Tukey test, with significance of 5% were used for statistical analysis of the data. Result A statistically significant difference was observed between the groups with and without treatment for insertion torque (p <0.001) and pullout test (p = 0.006), being the highest mean for the treatment group, regardless of the design. In the comparison between the designs, the thread presented a significantly higher average (p <0.001) than the helicoid. Conclusion The nanometric surface treatment enabled better mechanical performance of the mini-implants evaluated. With respect to the new designs tested, the thread presented superior results to the helicoidal one.


Assuntos
Implantes Dentários , Torque , Eficiência , Propriedades de Superfície , Revestimento de Dentadura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...